Cell-to-pack (CTP) and cell-to-chassis (CTC) construction has cut the space available for every component inside the battery enclosure. The cell contact system (CCS), which carries both the series power connection and the voltage and temperature sampling path, is where this constraint shows up first.
In a conventional module the harness was routed after stacking. In a 24S1P prismatic module for CTP/CTC, the same stack height must absorb busbar, bracket, sampling conductor and film at once. The YC-24S1P-7240 assembly is used here as a reference.
A wire harness is a three-dimensional object: bend radius, routing path and clearance all consume volume that CTP/CTC layouts no longer provide.
The bundle has to be routed around the cell stack, so it is pushed into the gap between top cap and lid: the same space the busbar and connector need. Designers either raise the lid or reduce sampling points.
Between two clamps the conductor resonates freely, so vibration reaches the terminal solder joint and that joint becomes the fatigue location. The usual countermeasure, more clamps, adds parts and inspection steps.
Sampling accuracy depends on connection integrity, not on the sensing circuit alone. Resistance drift at a work-hardened terminal is read by the BMS as a cell voltage change, and one degraded joint can shift balancing logic across a 24S string.
The circuit zone of this assembly is approximately 0.34 mm thick. Because the pattern is flat, it folds through 90° or 180° without a bend-radius reserve, so it follows a CTP/CTC contour or folds back during assembly. Signal and return paths share one layer stack, fixing loop area by design rather than by routing practice.
Flexibility is not wanted everywhere. At connector and mounting points the FPC is bonded to a rigid PCB stiffener, which holds contact position under insertion force and keeps the pad flat in the bracket.
The assembly is laminated with a black PET hot-press adhesive film (epoxy thermoset), rated 165 °C, UL94-V0, halogen-free. The film fixes the conductor pattern to the cell pitch and provides the dielectric barrier to the busbar. Being thermoset, it does not reflow at operating temperature, so registration survives thermal cycling.
The power path uses 1060-O aluminum at 1.5 mm. The annealed temper gives formability for the stepped geometry between adjacent terminals and avoids the spring-back that complicates positioning with harder tempers. Section is set against continuous current.
The tab linking busbar to terminal is arch-formed, not flat. The arch is a compliant element: under welding heat and vibration it absorbs displacement before it reaches the weld nugget. Its dimensions set both the current-carrying section and the stiffness of the compliant zone.
Two NTC thermistors, 10 kΩ ±1% with B value 3435, are fitted. The 1% tolerance bounds temperature error without per-unit calibration, and the specified B value keeps the error curve consistent across the range. Placement, not count, decides whether the reading represents the module.
| Check item | Confirm | Reference value |
|---|---|---|
| Series and layout | Busbar count, staggered arrangement | 24S1P, staggered |
| Cell and pitch | Pitch and bracket diameter | DFD-48168 3.2 V 40 Ah, 49.7 mm, 48.7 mm |
| Envelope | Height at the highest point | 288.5 * 174.5 * 18.5 mm, 110 g |
| Fold sequence | Angles used in assembly | 90° / 180°, zone approx. 0.34 mm |
| Dielectric class | Thermal and flame rating | 165 °C, UL94-V0, halogen-free |
| Power section | Material and thickness | 1060-O aluminum, 1.5 mm |
| Joint relief | Compliance before the weld | Arch nickel tab 22 * 7 * 1.3 mm |
| Sampling | Count, tolerance, B value | 2 * NTC 10 kΩ ±1%, B 3435 |
| Ribbon interface | Count and pitch | 4P / 12P / 14P, 220 mm, 2.54 mm |
A wire harness and an FPC-based CCS are not interchangeable at drawing level. A flat laminated assembly changes bend allowance, fixation strategy and sampling definition, and those points must be settled before the first sample is pressed.
Cell-to-pack (CTP) and cell-to-chassis (CTC) construction has cut the space available for every component inside the battery enclosure. The cell contact system (CCS), which carries both the series power connection and the voltage and temperature sampling path, is where this constraint shows up first.
In a conventional module the harness was routed after stacking. In a 24S1P prismatic module for CTP/CTC, the same stack height must absorb busbar, bracket, sampling conductor and film at once. The YC-24S1P-7240 assembly is used here as a reference.
A wire harness is a three-dimensional object: bend radius, routing path and clearance all consume volume that CTP/CTC layouts no longer provide.
The bundle has to be routed around the cell stack, so it is pushed into the gap between top cap and lid: the same space the busbar and connector need. Designers either raise the lid or reduce sampling points.
Between two clamps the conductor resonates freely, so vibration reaches the terminal solder joint and that joint becomes the fatigue location. The usual countermeasure, more clamps, adds parts and inspection steps.
Sampling accuracy depends on connection integrity, not on the sensing circuit alone. Resistance drift at a work-hardened terminal is read by the BMS as a cell voltage change, and one degraded joint can shift balancing logic across a 24S string.
The circuit zone of this assembly is approximately 0.34 mm thick. Because the pattern is flat, it folds through 90° or 180° without a bend-radius reserve, so it follows a CTP/CTC contour or folds back during assembly. Signal and return paths share one layer stack, fixing loop area by design rather than by routing practice.
Flexibility is not wanted everywhere. At connector and mounting points the FPC is bonded to a rigid PCB stiffener, which holds contact position under insertion force and keeps the pad flat in the bracket.
The assembly is laminated with a black PET hot-press adhesive film (epoxy thermoset), rated 165 °C, UL94-V0, halogen-free. The film fixes the conductor pattern to the cell pitch and provides the dielectric barrier to the busbar. Being thermoset, it does not reflow at operating temperature, so registration survives thermal cycling.
The power path uses 1060-O aluminum at 1.5 mm. The annealed temper gives formability for the stepped geometry between adjacent terminals and avoids the spring-back that complicates positioning with harder tempers. Section is set against continuous current.
The tab linking busbar to terminal is arch-formed, not flat. The arch is a compliant element: under welding heat and vibration it absorbs displacement before it reaches the weld nugget. Its dimensions set both the current-carrying section and the stiffness of the compliant zone.
Two NTC thermistors, 10 kΩ ±1% with B value 3435, are fitted. The 1% tolerance bounds temperature error without per-unit calibration, and the specified B value keeps the error curve consistent across the range. Placement, not count, decides whether the reading represents the module.
| Check item | Confirm | Reference value |
|---|---|---|
| Series and layout | Busbar count, staggered arrangement | 24S1P, staggered |
| Cell and pitch | Pitch and bracket diameter | DFD-48168 3.2 V 40 Ah, 49.7 mm, 48.7 mm |
| Envelope | Height at the highest point | 288.5 * 174.5 * 18.5 mm, 110 g |
| Fold sequence | Angles used in assembly | 90° / 180°, zone approx. 0.34 mm |
| Dielectric class | Thermal and flame rating | 165 °C, UL94-V0, halogen-free |
| Power section | Material and thickness | 1060-O aluminum, 1.5 mm |
| Joint relief | Compliance before the weld | Arch nickel tab 22 * 7 * 1.3 mm |
| Sampling | Count, tolerance, B value | 2 * NTC 10 kΩ ±1%, B 3435 |
| Ribbon interface | Count and pitch | 4P / 12P / 14P, 220 mm, 2.54 mm |
A wire harness and an FPC-based CCS are not interchangeable at drawing level. A flat laminated assembly changes bend allowance, fixation strategy and sampling definition, and those points must be settled before the first sample is pressed.